Rev. bras. cardiol. invasiva ; 21(4): 326-331, out.-dez. 2013. tab
Article in Portuguese | LILACS, SES-SP | ID: lil-703683

ABSTRACT

INTRODUÇÃO: Suportes vasculares bioabsorvíveis (SVB) têm sido desenvolvidos como forma de fornecer sustentação à parede do vaso enquanto ocorre o processo de cicatrização, após a intervenção coronária percutânea (ICP), sendo absorvido posteriormente. Pelo fato da plataforma ser de material polimérico, existe preocupação em relação à retração aguda do dispositivo. Avaliamos aqui a retração aguda do SVB com a de dois diferentes stents farmacológicos metálicos. MÉTODOS: Foram incluídos 50 pacientes com lesões não complexas. Dentre esses pacientes, 25 foram tratados com SVB e comparados a outros 25 pacientes tratados com stent de cromo-cobalto eluidor de everolimus (EES; n = 12) ou stent de aço inoxidável eluidor de biolimus (BES; n = 13). A retração aguda foi definida como a diferença entre o diâmetro médio do balão durante a pressão máxima de inflação (X) e o diâmetro médio do stent após o esvaziamento do balão (Y). A porcentagem de retração aguda foi definida como (X - Y)/X. RESULTADOS: Não houve diferença significativa em relação às características clínicas e angiográficas basais. O ganho luminal agudo foi menor com o SVB comparado ao EES e ao BES (1,51 ± 0,41 mm vs. 1,76 ± 0,28 mm vs. 1,9 ± 0,42 mm; P = 0,02). A retração aguda foi de 0,21 ± 0,13 mm vs. 0,15 ± 0,08 mm vs. 0,14 ± 0,08 mm (P = 0,21), e o porcentual de retração aguda foi de 7,0 ± 4,6% vs. 5,0 ± 2,2% vs. 5,7 ± 4,1% (P = 0,16). CONCLUSÕES: O SVB demonstrou ter retração aguda ligeiramente maior, embora não significativa, que os stents metálicos farmacológicos de segunda geração.


BACKGROUND: Bioresorbable vascular scaffolds (BVS) have been developed to provide support to the vessel wall during the healing process after percutaneous coronary intervention (PCI), being reabsorbed afterwards. Because the scaffold is made of polymeric material, there is a concern regarding the acute recoil of the device. We compared the BVS acute recoil with that of two different metallic drug-eluting stents. METHODS: Fifty patients with non-complex lesions were included. Twenty-five of these patients were treated with a BVS who were compared to 25 patients treated with a cobalt-chromium everolimus-eluting stent (EES, n = 12) or a stainless steel biolimus-eluting stent (BES, n = 13). Acute recoil was defined as the difference between the mean diameter of the balloon during maximum inflation pressure (X) and the mean diameter of the stent immediately after balloon deflation (Y). The percentage of acute recoil was defined as (X-Y)/X. RESULTS: There was no significant difference in the baseline clinical and angiographic characteristics. Acute luminal gain was lower with BVS compared to EES and BES (1.51 ± 0.41 mm vs. 1.76 ± 0.28 mm vs. 1.9 ± 0.42 mm, P = 0.02). Acute recoil was 0.21 ± 0.13 mm vs. 0.15 ± 0.08 mm vs. 0.14 ± 0.08 mm (P = 0.21) and the percentage of acute recoil was 7.0 ± 4.6% vs. 5.0 ± 2.2% vs. 5.7 ± 4.1% (P = 0.16). CONCLUSIONS: BVS presented a slightly higher, although not significant, acute recoil than the two second-generation metallic drug-eluting stents.


Subject(s)
Humans , Male , Female , Middle Aged , Absorbable Implants , Percutaneous Coronary Intervention/methods , Drug-Eluting Stents , Coronary Angiography/methods , Analysis of Variance , Retrospective Studies
2.
Rev. bras. cardiol. invasiva ; 21(4): 332-337, out.-dez. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-703684

ABSTRACT

INTRODUÇÃO: A conformabilidade do stent, definida como a adaptação da prótese à forma natural do vaso, é a principal responsável pelas alterações geométricas produzidas após o implante do dispositivo, sendo influenciada pelo material e pelo desenho do stent. Ela pode ser aferida medindo-se as modificações da curvatura e a angulação do segmento tratado após o implante do stent. O objetivo deste estudo foi comparar as mudanças na angulação coronária após implante do suporte vascular bioabsorvível (SVB) e das plataformas metálicas de cromo-cobalto e aço inoxidável, utilizadas em stents farmacológicos de segunda geração. MÉTODOS: Foram incluídos, nesta análise retrospectiva, 50 pacientes com lesões únicas, de novo, em coronárias nativas, com diâmetro entre 2,5 e 3,5 mm e extensão de até 23 mm. Vinte e cinco pacientes foram tratados com SVB e 25 pacientes com plataformas metálicas de cromo-cobalto (n = 12) ou de aço inoxidável (n = 13). A angulação foi medida usando um software de angiografia coronária quantitativa dedicado. RESULTADOS: A angulação do vaso modificou-se significativamente após o implante dos dispositivos. No grupo submetido ao implante de plataformas metálicas, houve maior modificação do ângulo coronário quando comparado ao tratado com SVB (41,6% vs. 14,9%; P < 0,01). Quando observado o comportamento do SVB e das diferentes plataformas metálicas, a alteração do ângulo coronário foi maior para as plataformas de aço inoxidável, seguida das plataformas de cromo-cobalto e os SVB (53,7% vs. 28,5% vs. 14,9%; P < 0,01). CONCLUSÕES: Nesta avaliação preliminar, o SVB produziu uma menor mudança da angulação coronária. O impacto clínico deste achado necessita ser investigado prospectivamente em uma coorte maior e mais complexa.


BACKGROUND: The conformability of the stent, defined as the adaptation of the prosthesis to the natural shape of the vessel, is the major cause of geometrical changes after stenting and is influenced by the stent material and design. It may be assessed by measuring changes in the curvature and the angulation of the treated segment after stent implantation. The objective of this study was to compare changes in coronary angulation after implantation of the bioresorbable vascular scaffold (BVS) and cobalt-chromium and stainless steel metal platforms used in second-generation drug-eluting stents. METHODS: In this retrospective analysis, 50 patients with single de novo lesions in native coronary arteries and diameter between 2.5 and 3.5 mm and length up to 23 mm were included. Twenty-five patients were treated with BVS and 25 patients were treated with cobalt-chromium (n = 12) or stainless steel (n = 13) platforms. Angulation was measured using a dedicated quantitative angiography analysis software. RESULTS: Vessel angulation significantly changed after device implantation. In the group submitted to the implantation of metal platforms there was greater coronary angulation change when compared to the group treated with BVS (41.6% vs. 14.9%; P < 0.01). When we analyzed the performance of the BVS and the different metal platforms, coronary angulation change was greater for the stainless steel platforms, followed by cobalt-chromium platforms and the BVS (53.7% vs. 28.5% vs. 14.9%; P < 0.01). CONCLUSIONS: In this preliminary assessment, the BVS produced a smaller coronary angulation change. The clinical impact of this finding must be prospectively investigated in a larger and more complex cohort.


Subject(s)
Humans , Male , Female , Middle Aged , Absorbable Implants , Coronary Vessels , Drug-Eluting Stents , Coronary Angiography/methods , Retrospective Studies , Stents
3.
Rev. bras. cardiol. invasiva ; 21(1): 23-29, jan.-mar. 2013. ilus, tab
Article in Portuguese | LILACS, SES-SP | ID: lil-674484

ABSTRACT

INTRODUÇÃO: A embolização de fragmentos de ateroma/trombo durante a intervenção coronária percutânea (ICP) ocasiona distúrbios de perfusão da microcirculação. O novo stent MGuardTM, que é revestido com uma rede de polietileno, demonstrou eficácia na prevenção de complicações embólicas durante a ICP primária. No entanto, a evolução clínica tardia de pacientes tratados com o stent MGuardTM permanece desconhecida. MÉTODOS: Uma série de 65 pacientes portadores de lesões coronárias de novo tratados com o stent MGuardTM foi analisada. Os dados clínicos basais, do procedimento e do seguimento clínico tardio (média de tempo, 2,6 ± 1,4 anos) foram coletados retrospectivamente por meio da revisão de prontuários médicos e/ou contato telefônico direto. RESULTADOS: A média de idade foi de 66,1 ± 13,7 anos, 32,3% eram diabéticos, 49,2% tinham infarto agudo do miocárdio (IAM) prévio, e 44,6% apresentaram-se com síndrome coronária aguda. Dois terços das lesões estavam localizados em pontes de safena, quase metade tinha presença de trombo e a maioria foi classificada como tipo B2/C. O stent MGuardTM foi implantado com sucesso em todos os casos. Ao final do procedimento, fluxo TIMI 3 foi alcançado em 93,4% e o sucesso angiográfico foi de 91,8%. No seguimento tardio, as taxas de eventos adversos incluíram óbito cardiovascular em 6,2%, IAM não-fatal em 9,2%, revascularização da lesão-alvo em 9,2% e trombose de stent definitiva/provável em 1,5%. CONCLUSÕES: O seguimento tardio de pacientes com lesões coronárias complexas tratados com o stent MGuardTM demonstrou baixas taxas de revascularização da lesão-alvo e de trombose do stent.


BACKGROUND: The embolization of atheroma/thrombus fragments during percutaneous coronary intervention (PCI) causes microcirculatory perfusion disturbances. The new MGuardTM, a mesh-based bare-metal stent, demonstrated efficacy in the prevention of embolic complications during primary PCI. However, the late clinical outcome of patients treated with the MGuardTM stent remains unknown. METHODS: A series of 65 patients with de novo coronary lesions treated with MGuardTM stent was analyzed. Baseline clinical data, procedure and late clinical follow-up (mean duration, 2.6 ± 1.4 years) data were collected retrospectively by a review of medical records and/or direct telephone contact. RESULTS: Mean age was 66.1 ± 13.7 years, 32.3% of patients were diabetic, 49.2% had a previous acute myocardial infarction (AMI), and 44.6% presented with acute coronary syndrome. Two thirds of the lesions were located in a saphenous vein graft, almost half of the lesions had thrombus and most were classified as type B2/C. The MGuardTM stent was successfully implanted in all cases. At the end of the procedure, TIMI 3 flow was achieved in 93.4% and angiographic success was 91.8%. In the late clinical follow-up, adverse event rates included cardiac death in 6.2%, non-fatal AMI in 9.2%, target lesion revascularization in 9.2% and definite/probable stent thrombosis in 1.5%. CONCLUSIONS: The late follow-up of patients with complex coronary lesions treated with the MGuardTM stent demonstrated low rates of target lesion revascularization and stent thrombosis.


Subject(s)
Humans , Male , Female , Angioplasty/methods , Stents , Coronary Thrombosis/physiopathology , Embolism/etiology , Observational Studies as Topic , Heparin/administration & dosage , Platelet Aggregation Inhibitors , Percutaneous Coronary Intervention/methods